Independent Indramat specialistsSan Antonio · Ramos Arizpe

ECODRIVE comparison / controller identity

DKC01 vs DKC02 vs DKC03 Drive Controllers

DKC01, DKC02 and DKC03 are separate controller groups, and the design number after the decimal is also meaningful. A similar enclosure or current code does not establish that command communication, feedback, firmware or motor support is the same.

Bottom line

What this comparison can establish

Match the complete DKC code, design generation, current and voltage fields, command interface, feedback support, firmware and connected motor. Do not substitute from the DKC prefix alone.

Side-by-side identity

What each product label must tell you

Role
ECODRIVE controller group documented independently from DKC02 and DKC03.
Verify
Complete .1 or .3 designation, current and voltage fields, interface, feedback, firmware and motor.
Do not assume
DKC01 and DKC11 may share documentation in some editions; that does not make every configured unit equivalent.
Role
A separate ECODRIVE controller group with its own planning records and interface context.
Verify
Complete design code, current class, command communication, feedback, firmware and installed-system labels.
Do not assume
Do not infer DKC02 compatibility from current rating or cabinet dimensions alone.
Role
A distinct ECODRIVE controller group represented across more than one documented generation.
Verify
Digits on both sides of the decimal, suffix, firmware, feedback, interface, motor and supply context.
Do not assume
DKC03.1 and ECODRIVE03 DKC03.3 material must be checked against the applicable edition.

Decision path

Turn the cabinet into a useful evidence set

01

Which controller group is installed?

Capture: Photograph the complete DKC01, DKC02 or DKC03 line exactly as printed.

Then: Open the matching family page and edition-specific official record.

02

Which hardware generation is it?

Capture: Keep the number after the decimal and all suffix fields.

Then: Reject a match that silently drops or changes the design generation.

03

What does the machine require?

Capture: Record motor, feedback cable, command network, firmware and supply architecture.

Then: Compare the configured system—not only the base controller.

Official manufacturer records

Use the edition that matches the installed hardware.

Verified downloads open on the manufacturer’s site. Other references open a library entry with assistance options. Confirm the applicable edition, physical nameplate and machine documentation.

Common questions

Before you request a configured match

Can I replace a DKC01 with a DKC02 or DKC03?

A family-name comparison cannot approve that change. The exact hardware, interface, feedback, firmware, motor and machine design must be reviewed together.

Does the number after the decimal matter?

Yes. It identifies a design generation or edition context that must remain attached to the rest of the code.

Is FW a complete firmware specification?

No. FW in a designation does not by itself identify the required firmware family, release, parameters or what is included with a unit.

Availability · repair · exchange

Send the complete code.

The suffix can change electrical and mechanical compatibility. Include every character and a clear nameplate photo.